P07303 Series Customer Display User Manual 2007 August V1.
Copyright 2007’ August All Rights Reserved Manual Version 1.7 The information contained in this document is subject to change without notice. We make no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. We shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material.
Safety IMPORTANT SAFETY INSTRUCTIONS 1. To disconnect the machine from the electrial power supply, turn off the power switch and remove the power cord plug from the wall socket. The wall socket must be easily accessible and in close proximity to the machine. 2. Read these instructions carefully. Save these instructions for future reference. 3. Follow all warnings and instructions marked on the product. 4. Do not use this product near water. 5. Do not place this product on an unstable cart,stand,or table.
LEGISLATION AND WEEE SYMBOL 2002/96/EC Waste Electrical and Electronic Equipment Directive on the treatment, collection, recycling and disposal of electric and electronic devices and their components. The crossed dustbin symbol on the device means that it should not be disposed of with other household wastes at the end of its working life. Instead, the device should be taken to the waste collection centers for activation of the treatment, collection, recycling and disposal procedure.
Table of Contents 1. DIP SWITCH AND SOFTWARE SETTING........................................ 6 1.1. 1.2. 1.3. 1.4. 1.5. COMMAND TYPE SELECTION ............................................................................ 6 BAUD RATE SELECTION ................................................................................... 6 PARITY CHECK SELECTION ............................................................................... 6 COMMAND CONTROL ..............................................................
1. Dip Switch and Software Setting 1.1. Command Type Selection SW1 ON OFF ON OFF ON OFF ON OFF 1.2. SW2 ON ON OFF OFF ON ON OFF OFF SW9 ON ON OFF OFF Demo Mode Support No Yes No Yes No No No Yes Baud Rate (bps) 4800 9600 19200 38400 Default * Parity Check Selection SW10 ON OFF 1.4. Command Type POS7300 EPSON ESC/POS ADM 787/ ADM 788 DSP800 AEDEX/ EMAX UTC/P UTC/S CD5220 Baud Rate Selection SW8 ON OFF ON OFF 1.3.
1.5. International Character Set ID SW SW SW SW SW Character Set 4 5 6 7 11 (20h – 7Fh) 0 ON ON ON ON OFF U.S.A.
2. Software Status Setting Commands When the system is POWER ON, it will read the DIP switch to set the Command Type, Baud Rate, Parity, Demo Mode and International Character. User can re-set the Software Status Setting Commands as following: 2.1. Baud Rate Setting Command STX 05 B n ETX ASCII Format Dec. Format Hex. Format Description /Change the baud rate setting/ STX 05 B n ETX [02] [05] [66] n [03] [02h][05h][42h] n [03h] 30h≦n≦33h Change the display communication baud rate.
2.3. International Character Set Setting Command STX 05 S n ETX ASCII Format Dec. Format Hex. Format Description n /Change the international character set/ STX 05 S n ETX [02] [05] [83] n [03] [02h][05h][53h] n [03h] 30h≦n≦4Fh Change the display international character font. Character Set (20h – 7Fh) 30h U.S.A. 31h 32h 33h 34h 35h 36h 37h 38h 39h 3Ah 3Bh 3Ch 3Dh 3Eh 3Fh 40h 41h 42h 43h 44h 45h 46h 47h FRANCE GERMANY U.K. DENMARK I SWEDEN ITALY SPAIN JAPAN NORWAY DENMARK II Slawie RUSSIA U.S.A U.K.
2.4. Command Type Setting Command STX 05 C n ETX ASCII Format Dec. Format Hex. Format Description n 30h 31h 32h 33h 2.5. Command Type POS7300 ESC/POS ADM 787 DSP800 n 34h 35h 36h 37h Command Type AEDEX UTC/P UTC/S CD5220 Run Demo message STX 05 D 08 ETX ASCII Format Dec. Format Hex. Format Description 2.6. /Change the command type setting/ STX 05 C n ETX [02] [05] [67] n [03] [02h][05h][43h] n [03h] 30h≦ n ≦37h This command will change the command type and initialize the display.
3.
Command List Table – 2 POS7300CD5220 Upper line message continuous scroll Bottom line message scroll continuously Message vertical down scroll continuously Message vertical upper scroll continuously Carriage return Line feed Back space Horizontal tab Command type select Upper line message scroll once pass Change attention code Two line display Clear upper line and move cursor to upper left-end position Clear bottom line and move cursor to bottom left-end position Set period to upper line, last n position S
4. Command Details 4.1.
POS7300 Standard Mode Command List-2 Command BS HT LF HOM CLR CR CAN ESC = n Code (hex) 08 09 0A 0B 0C 0D 18 1B 3D n Function Description Back space Horizontal tab Line feed Move cursor to home position Clear display screen Carriage return Clear cursor line, and clear string mode Select peripheral device, display or printer ¾ n = 1~3 n = '1': enable printer only n = '2': enable display only n = '3': enable both of printer and display 14
4.2.
CD5220 Standard Mode Command List-2 Command Code (hex) ESC W s x1 x2 y 1B 57 s x1 x2 y CLR CAN ESC * n US X n ESC _ n 0C 18 1B 2A n 1F 58 n 1B 5F n ESC f n 1B 66 n ESC c n 1B 63 n ESC = n 1B 3D n Function Description Set or cancel the window range at horizontal scroll mode ¾ 1 ≦ x1 ≦ x2 ≦ 14h, for columns location. ¾ y = 1~2, for lines location.
4. The parameter of the code table control by command “ESC c n”.
4.3. UTC Standard Mode Command List Command BS HT LF CR DLE n 08 09 0A 0D 10 n DC1 DC2 DC3 DC4 US ESC d 11 12 13 14 1F 1B 64 4.4. Code (hex) Function Description Back space Horizontal tab Line feed Carriage return Display position ¾ n = 0 ~ 27h, for location.
4.5. AEDEX/EMAX Mode Command List Command Code (hex) ! # 4 [DATA] 21 23 34 [DATA] 0D CR ! # 5 h h : m m 21 23 35 h h ':' m m 0D CR ! # 8 n m CR 21 23 38 n m 0D ! # 9 [DATA] CR ! # 6 [DATA] CR 4.6.
4.7.
4.8. EPSON ESC/POS Command List EPSON ESC/POS Command List-1 Command Code (hex) Function Description US r n 1F 72 n Select/cancel reverse character. ¾ n = 00,01 US MD1 1F 01 Specify overwrite mode. US MD2 1F 02 Specify vertical scroll mode. US MD3 1F 03 Specify horizontal scroll mode. CAN 18 Clear cursor line ESC # n 1B 23 n Command type select ¾ n = 30h ~ 38h US # n x 1F 23 n x Turn annunciator on/off. ¾ n = 0 for annunciator off n = 1 for annunciator on ¾ x = 1 ~ 14h, for columns location.
EPSON ESC/POS Command List-2 Command Code (hex) Function Description US ^ n m 1F 5E n m Execute and quit macro. It’s an interval of n between the two words. It’s an interval of m between the two strings.
5. Character Set 5.1. Character Code 20H – 7FH 5.1.
5.2. 5.2.1 80h 90h A0h B0h C0h D0h E0h F0h 5.2.2 80h 90h A0h B0h C0h D0h E0h 5.2.
5.2.4 80h 90h Katakana for Japan 00h 01h 02h 03h 04h 05h 06h 07h 08h 09h 0Ah 0Bh 0Ch 0Dh 0Eh 0Fh α £ A0h β γ ⊿ є η θ § IE IR ∫ x Ā 。 「 」 、 ‧ λ -1 μ ² π ³ ρ x σ τ Ф Ω ∑ ½ 1/ √ ± ■ B0h C0h D0h E0h F0h 5.2.
80h 90h A0h B0h C0h D0h E0h F0h 5.2.
90h A0h B0h C0h D0h E0h F0h 5.2.11 80h 90h B0h C0h D0h E0h F0h 5.2.
A0h B0h C0h D0h E0h F0h 5.2.14 80h 90h A0h B0h C0h D0h E0h F0h 5.2.15 80h а ░ └ ╨ р Ё Ђ Ѓ ђ ‘ Ў ° ± А Б Р С а б р с D0h E0h F0h 5.2.
B0h C0h D0h E0h F0h 5.2.17 80h 90h A0h B0h C0h D0h E0h F0h ° ְ ׀ א נ ± ֱ ׁ ב ס ² ֲ ׂ ג ע ³ ֳ ׃ ד ף ´ ִ װ ה פ µ ֵ ױ ו ץ ¶ ֶ ײ ז צ · ַ ׳ ח ק ¸ ¹ ÷ ָ ֹ ״, : ך י ט ת ש ר » ֻ ; כ ¼ ½ ¾ ¿ ּ ֽ ֿ ־ .
Appendix A - Command Details A.1. Overwrite mode In this mode, the cursor will move rightward and begin from the upper left-end position. When the cursor has reached the end of the upper line, the cursor will move down to the bottom left-end position to continue. When the cursor has reached the end of the bottom line, it will move to up the upper left-end position and overwrite the previous characters. A.2. Vertical scroll mode In this mode, the cursor will move rightward.
A.7. Move cursor right Move the cursor to the right. When the cursor has reached the right-end, this command operates differently depending on the display mode. Overwrite mode: When the cursor has reached the right-end of the lower line, it will continue to the left-end of the upper line and overwrite previous characters. When it has reached the right-end of the upper line, it will continue to the right-end of the lower line.
A.14. Move cursor to specified position The cursor will be moved to column x on line y. A.15. Initialize display The data in the input buffer will be cleared and reset from default. A.16. Reset the window Reset the window on the display. When s=0, the window is cancelled (values: x1, x2, and y are not required.) When s=1, the window will be reset (values: x1, x2, and y are required.) The x1 and x2 set the position of the left column and right column, respectively, of the window.
Appendix B - Control Code Set HEX 00H 01H 02H 03H 04H 05H 06H 07H 08H 09H 0AH 0BH 0CH 0DH 0EH 0FH CODE NULL SOH, MD1 STX, MD2 ETX, MD3 EOT, MD4 ENQ, MD5 ACK, MD6 BEL, MD7 BS, MD8 HT LF VT, HOM FF, CLR CR SO, SLE1 SI, SLE2 HEX 10H 11H 12H 13H 14H 15H 16H 17H 18H 19H 1AH 1BH 1CH 1DH 1EH 1FH 33 CODE DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS, SF1 US, SF2