Color Inkjet Printer Service Manual
Table Of Contents
- EPSON Stylus Photo R300/R310
- TROUBLESHOOTING
- DISASSEMBLY AND ASSEMBLY
- 2.1 Overview
- 2.2 Caution regarding assembling/disassembling the printer mechanism, a·Yl|Z6±¬¨–‹šÒq¿GZ~YçlçXX
- 2.3 Disassembly
- 2.3.1 Removing Paper Support Assy.
- 2.3.2 Removing Housing, Upper
- 2.3.3 Removing Housing, Middle
- 2.3.4 Removing Porous Pad, Paper Guide, Front
- 2.3.5 Removing Panel Board
- 2.3.6 Removing Stacker Assy.
- 2.3.7 Removing Main Board
- 2.3.8 Removing ASF Assy.
- 2.3.9 Removing Holder, Shaft Assy.
- 2.3.10 Removing CR Motor
- 2.3.11 Removing APG Assy.
- 2.3.12 Removing Print Head
- 2.3.13 Removing Carriage Unit
- 2.3.14 Removing Paper Guide, Upper
- 2.3.15 Removing Printer Mechanism/ Housing, Lower
- 2.3.16 Removing Power Supply Unit
- 2.3.17 Removing CDR Guide Assy.
- 2.3.18 Removing Ink System
- 2.3.19 Removing Paper Guide, Front/Roller EJ Assy.
- 2.3.20 Removing PF Motor
- ADJUSTMENT
- 3.1 Adjustment Items and Overview
- 3.2 Adjustment by using adjustment program
- 3.2.1 Market Setting
- 3.2.2 USB ID Input
- 3.2.3 Head ID Input
- 3.2.4 Head Angular Adjustment
- 3.2.5 Bi-d Adjustment
- 3.2.6 PW Sensor Adjustment
- 3.2.7 First Dot Adjustment
- 3.2.8 Offset Input for CR Motor Calorific Limitation
- 3.2.9 A4 Normal Paper Print
- 3.2.10 A4 Photo Quality Inkjet Paper Print
- 3.2.11 A4 Photo Paper/ Glossy Photo Paper print
- 3.3 Adjustment Except Adjustment Program
- MAINTENANCE
- APPENDIX

Stylus Photo R300/R310 Revision A
DISASSEMBLY AND ASSEMBLY Disassembly 42
When removing "Housing, Middle", the grounding spring may
detach and drop from "Main Board Unit". If this occurs,
reattach it to its original position referring to the following
figure.
Figure 2-7. Reattaching the Ground Spring
Make sure to mount "Panel FFC" passing under the hooks as
shown in the figure and then secure "Panel FFC" with a two-
sided tape.
Make sure that "Panel FFC" is securely set and it is not reaching
the upper edge of the rib of "Housing, Middle" as shown in the
figure.
Figure 2-8. Mounting "Panel FFC"
Grounding
Spring
Rib
Keep some clearance here.
Make sure that the connector cable of "Power Supply Board" is
securely set in the groove of "Housing, Lower".
Figure 2-9. Mounting the Connector Cable
Make sure that "Panel FFC" is not stuck under "Housing,
Middle".
Make sure to tighten up the screws on the back of "Housing,
Middle" in the order as shown in the figure.
Groove
Connector Cable