User`s guide
11. Remote Control
EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 265
Error response
When the Controller can not receive the remote command correctly, the error response is
shown in the following format.
Format: ![Remote command],[Error code] terminator
Error code Contents
10
Remote command does not begin with $
11
Remote command is wrong
Login is not executed
12
Remote command format is wrong
13
Login command password is wrong
14
Specified number to acquire is out of range
(Less than 1 or more than 100)
Number to acquire is omitted
Specified a string parameter
15
Parameter is not existed
Dimension of parameter is wrong
Element out of range is called
19
Request time out
20
Controller is not ready
21
Cannot execute since the Execute is running
99
System error
Communication error
Communication sequence
Controller
IP xxx.xxx.xxx.xxx
Ethernet Client
IP zzz.zzz.zzz.zzz
(1)
Login
(2) Response
(3) Command request
(4) Response
(5) Logout
(6) Response
Request from
zzz.zzz.zzz.zzz:zz
is only available
:
: