Examples:
To enable software suspend mode, use the following arguments:
/software /enable
To disable software suspend mode, use the following arguments:
/software /disable
To enable the LCD, use the following arguments:
/lcd /enable
To disable the LCD, use the following arguments:
/lcd /disable
7.4 Comments
• The /i argument is to be used when the registers have not been previously initialized.
•
The PC must not have more than 12M bytes of memory when used with the S5U13504P00C board.
• Follow simultaneous display guidelines for correct simultaneous display operation.
• Do not use a dual panel with a CRT. Select “Panel Single” whenever using a CRT, even if a panel
is not attached. Also, the panel section of 13504CFG must be programmed to “Single Panel.”
• When a CRT is enabled, the settings for the CRT will override the panel settings. If a panel is also
used, the CRT timing values will have to be changed to more closely match the panel's timing.
• A CRT cannot show 15 or 16 bits-per-pixel.
• Do not attach a 16-bit panel when using the CRT.
7.5 Program Messages
ERROR: Unknown command line argument.
An invalid command line argument was entered. Enter a valid command line argument.
ERROR: Already selected SOFTWARE.
Command line argument /software was selected more than once. Select /software only once.
ERROR: Already selected HARDWARE.
Command line argument /hardware was selected more than once. Select /hardware only once.
ERROR: Already selected ENABLE.
Command line argument /enable was selected more than once. Select /enable only once.
ERROR: Already selected DISABLE.
Command line argument /disable was selected more than once. Select /disable only once.
ERROR: Select /software or /hardware.
Neither command line argument /software or /hardware was selected. Select /software or /hardware.
ERROR: Select /enable or /disable.
Neither command line argument /enable or /disable was selected. Select /enable or /disable.
ERROR: Too many devices registered.
There are too many display devices attached to the HAL. The HAL can only manage 10 devices
simultaneously.
ERROR: Could not register S1D13504F00A device.
A 13504 device was not found at the configured addresses. Check the configuration address using
the 13504CFG configuration program.
ERROR: Did not detect S1D13504.
The HAL was unable to read the revision code register on the S1D13504. Ensure that the S1D13504