Installation guide
1. Safety 
RC180 Safety and Installation Rev.19  29 
Speed Overflow -Servo Error- Detection 
The dynamic brake circuit is activated when the Manipulator’s actual speed is 
detected to mark an overflow (the actual speed is outside the nominal range) error. 
CPU Irregularity Detection 
Irregularity of CPU that controls the motor is detected by the watchdog timer.  
The system CPU and the motor controlling CPU inside the Controller are also 
designed to constantly check each other for any discrepancies.    If a discrepancy is 
detected, the dynamic brake circuit is activated. 
Memory Check-sum Error Detection 
The dynamic brake circuit is activated when a memory check-sum error is 
detected. 
Overheat Detection at the Motor Driver Module 
The dynamic brake circuit is activated when the temperature of the power device 
inside the Motor Driver module is above the nominal limit. 
Relay Deposition Detection 
The dynamic brake circuit is activated when relay deposition is detected. 
Over-Voltage Detection 
The dynamic brake circuit is activated when the voltage of the Controller is above 
the normal limit. 
AC Power Supply Voltage Drop Detection 
The dynamic brake circuit is activated when the drop of the power supply voltage 
is detected. 
Temperature Anomaly Detection 
The temperature anomaly is detected. 
Fan Malfunction Detection 
Malfunction of the fan rotation speed is detected. 