Installation guide
2. Installation 
RC180 Safety and Installation Rev.19 
40 
2.4. Manipulator Installation 
Installation and transportation of robots and robotic equipment shall be performed 
by qualified personnel and should conform to all national and local codes. 
For details, refer to the Manipulator manual. 
Installation Precautions 
 Safeguard installation 
:  To ensure safety, a safeguard must be installed for the robot system.  
For details on the safeguard, refer to the Installation and Design 
Precautions in the Safety chapter of the EPSON RC+ User’s Guide. 
  Space between safeguard and Manipulator 
:  Install the Manipulator at a location with sufficient space so that a tool or 
a work piece on the end effector does not reach a wall or a safeguard 
when the Manipulator extends its arm fully while holding a work piece.   
Installing the Manipulator at a location with insufficient space is 
extremely hazardous and may result in serious bodily injury and/or 
severe equipment damage to the robot system as a tool or a work piece 
may collide with a wall and a safeguard. 
  Manipulator check before installation 
:  Before installing and operating the Manipulator, make sure that all parts 
of the Manipulator are in place and have no external defects.    Missing 
or defective parts may cause improper operation of the Manipulator. 
Improper operation of the Manipulator is extremely hazardous and may 
result in serious bodily injury and/or severe equipment damage to the 
robot system. 
  Side mounting and ceiling mounting 
: When mounting the Manipulator on a wall or ceiling, secure the 
Manipulator to the wall or ceiling that has enough strength and rigidity.   
Mounting the Manipulator on a wall or ceiling that has insufficient 
strength and rigidity is extremely hazardous and may result in serious 
bodily injury and/or severe equipment damage to the robot system as the 
Manipulator may fall or vibrate. 
  Side mounting and ceiling mounting 
: When mounting the Manipulator on a wall or ceiling, for safety 
purposes, attach the support to the Manipulator base to prevent the 
Manipulator from falling.  If the Manipulator falls, it is extremely 
hazardous and may result in serious bodily injury and/or severe 
equipment damage to the robot system. 