Service manual

Chapter1 Product Description
Rev. A
1-
8
1.2.5 Environmental Condition
Temperature
Operating :10 to 35 °C (Refer to the figure below for condition)
Non-operating : -20 to 60 °C(with shipment container)
Note)
1 month at 40 °C and 120 hours at 60 °C
Humidity
Operating : 20% 80% RH (without condensation. Refer to the figure below for
condition)
Non-operating : 5% 85% RH (without condensation and with shipment container)
Resistance to shock
Operating : 1G, within 1 ms X,Y,Z directions
Non-operating : 2G, within 2 ms X,Y,Z directions (with shipment container)
Resistance to vibration
Operating : 0.15G, 10 55Hz X,Y,Z directions
Non-operating : 0.50G, 10 55Hz X,Y,Z directions (with shipment container)
Note 1)
During non-operating, make sure that the head is capped.
Note 2)
During the transport, make sure that the head is capped and ink cartridge is
installed to the printer.
Note 3)
If the head is not capped at the power-off state, turn the power on with installed ink
cartridge and turn off the power after confirming that Power on operation is completed and
the head is capped.
Note 4)
Ink will be frozen under -4°C environment, however it will be useable after placing it
more than 3 hours at 25°C.
Humidity
(% RH)
°C
(°F)
80%
55%
20%
10°C
(50°F)
27°C
(80°F)
35°C
(95°F)
Guaranteed range
Figure 1-5. Temperature/Humidity of Range