Service manual
EPSON Stylus Photo 870/1270 Revision B
Disassembly And Assembly Disassembly Procedures 112
4. Set SCALE, PF onto BRACKET, SCALE with its front side facing
downward.
Figure 4-61. Attaching SCALE, PF
5. Remove the base sheet of TAPE, D50 and stick it to SCALE, PF.
Figure 4-62. TAPE, D50 Installation
6. Peel off the protection sheet from TAPE, D50 on SCALE, PF.
CAUTION
!
Do not touch the following areas:
- Inner side of the SCALE, PF’s shaft hole through which
the PF Roller Shaft is installed.
- Printed face of SCALE, PF
!
If BRACKET, SCALE is not aligned with the circle printed
on SCALE, PF, it should not be a problem.
Tool
(Code: 1051765)
SCALE, PF
Set the scale’s front
side facing downward.
Tool (Code: 1051765)
CAUTION
!
If TAPE, D50 is not aligned with the circle printed on
SCALE, PF, it should not be a problem.
TAPE, D50
Protection Sheet
SCALE, PF
Tool (Code: 1051765)
Protection Sheet