Maintenance Overview 139
6.1.2.3 Scanner Mechanism
This chapter provides information necessary to keep the scanner function in
optimum condition constantly and to prevent troubles.
When the carriage unit needs to be replaced, or the operation sound of the
carriage movement becomes noisy, it is necessary to apply lubrication.
Following tables show the recommended grease type and lubrication points.
Note*)
“E” means exclusive product for EPSON. (Not available on the market.)
Table 6-5. Recommended Grease
Type Name
Supply
Quantity
Part No. Specification
Grease G-26 40g B702600001 E*
Table 6-6. Lubrication points
Figure Lubrication Points Lubrication
6-1
Transmission Gear Shaft of the CR motor and
Driven pulley shaft.
G-26 (1x3mm)
6-1 Driven Pulley Shaft G-26(1x3mm)
CAUTION
Excessive lubrication may damage the mechanism part or
cause the malfunction of the operation.