Specifications

168
GS1 DataBar Expanded
Specify the data of 2 to 255 digits.
‘()’ is the delimiter for the application identifiers. (printed as the HRI character, but not
encoded.)
Be sure to include all the application identifiers in the data.
When the first data is ‘01’ after deleting application identifiers, left and right parenthesis, and
‘*’ from the specified data, the 14th digit from the next of ‘01’ is checked as a check digit. When
it is not correct, an error occurs.
When the next data of ‘01’ is fewer than 14 digits, a check digit is not checked.
(Unlike GS1-128, the check d
igit is not automatically calculated, nor replaced with ‘*.’ When ‘*’
is specified, ‘*’ is ignored, and the rest of the data is shifted by 1 digit.)
Specify the special character using the following format.
Printing method
Specify the selected barcode font, specified point and language to the printing data, and then
print it.
Control Character ASCII HRI Character
FNC1 {1 Space is printed.
Left parenthesis for the application identifier ( '(‘ is printed.
Right parenthesis for the application identifier ) ‘)’ is printed.
‘*’ {* Error
Skipped character * Not printed.
The font size of the barcode can not be changed by [Specified Point] value. The barcode is
not printed when other values are selected.