Specifications

General Information 1-7
TM-H6000/H6000P Developer’s Guide
Confidential
Panel Button Operations
The command
ESC c 5
can be set to enable or disable the panel buttons, but in some situations
the setting of
ESC c 5
is ignored, as you can see in the table below:
Switches
DIP Switches
The printer has two sets of DIP switches. The functions of the switches are shown in the
following tables.
Serial interface model
Normal Mode
All covers are
closed
Paper roll cover
is opened
Unit cover is
opened
Front cover is
opened
If receipt is
selected
FEED Follow ESC c 5 Disabled Disabled Follow ESC c 5
RELEASE Follow ESC c 5 Enabled
If slip is
selected
FEED Follow ESC c 5 Follow ESC c 5 Enabled Enabled
RELEASE Follow ESC c 5 Enabled
Slip insertion
waiting status
Slip ejection waiting status
All covers are
closed
Paper roll cover
is opened
Unit cover is
opened
Front cover is
opened
If receipt is
selected
FEED ————
RELEASE————
If slip is
selected
FEED Disabled Follow ESC c 5 Follow ESC c 5 Enabled Enabled
RELEASE Disabled Follow ESC c 5 Enabled
Set 1
SW Function ON OFF
1-1 Data receive error Ignored Prints “?”
1-2 Receive buffer capacity 45 bytes 4K bytes
1-3 Handshaking XON/XOFF DTR/DSR
1-4 Data word length 7 bits 8 bits
1-5 Parity check Enabled Disabled
1-6 Parity selection Even Odd
1-7 Transmission speed (See the table below.)
1-8