Specifications

General Information 1-9
TM-H6000/H6000P Developer’s Guide
Confidential
Parallel interface specification
Print density
Notes:
Changes in DIP switch settings (excluding switch 2-8, interface reset signal) are recognized only when the printer
power is turned on or when the printer is reset by using the interface. If the DIP switch setting is changed after the
printer power is turned on, the change does not take effect until the printer is turned on again or is reset.
If you turn on DIP switch 2-8 while the printer is turned on, the printer may be reset, depending on the signal state.
DIP switches should not be changed while the printer power is on.
If the print density is set to level 3 or 4, printing speed is usually reduced.
Set 1
SW Function ON OFF
1-1 Auto line feed Always enabled Always disabled
1-2 Receive buffer capacity 45 bytes 4KB
1-3~
1-8
Reserved Fixed to OFF
Set 2
SW Function ON OFF
2-1 Handshaking
(BUSY condition)
Receive buffer full Offline or receive
buffer full
2-2 Internal use (Do not
change setting.)
Fixed to OFF
2-3
Print density (See the table below.)
2-4
2-5~
2-6
Internal use (Do not
change setting.)
Fixed to OFF
2-7 Reserved (for serial
interface)
Fixed to OFF
2-8 I/F pin 31 reset signal
(Do not change setting.)
Fixed to ON
Print Density SW 2-3 SW 2-4
1 (Light) ON ON
2
OFF OFF
3
ON OFF
4 (Dark) OFF ON