Specifications
Hardware 2-23
TM-H6000/H6000P Developer’s Guide
Confidential
❏
When using pin 25 (INIT) (DIP switch 2-8 is ON):
Minimum reset pulse width (pin 25)
NOTES:
• When a si
g
nal that does not satisf
y
the re
q
uirements above is input, printer operation is not
g
uaranteed. When a si
g
nal is
input to pin 25
(
INIT
)
at the TTL level, the re
q
uirements above must also be satisfied. Althou
g
h a si
g
nal is input to pin 6
(
DSR
)
at the TTL level, accordin
g
to the DC characteristics described above, the operation is not
g
uaranteed and pin 6
cannot be controlled.
• When pin 6
(
DSR
)
and pin 25
(
INIT
)
are open, the printer is operatin
g
.
IEEE 1284 Bidirectional Parallel Interface (Parallel Interface Specifications)
Copyright (C) 1994 by the Institute of Electrical and Electronic Engineers, Inc.
Compatibility mode (data transmission from host to printer: Centronics-compatible)
The printer is not equipped with any online/offline switch. The printer is placed into offline
status in any of the following conditions:
1. When the power is turned on or until the printer becomes ready for data transmission after it
is initialized by the reset signal (nInit) from the interface.
2. During the self-test.
3. When the cover is open.
4. During paper feeding using the
FEED
button.
5. When the printer stops printing due to a paper-end (only when the paper roll is not present).
6. During macro executing standby status.
Outline Compatibility mode supports the compatibility with
Centronics parallel interface.
Specifications Data transmission: 8-bit Parallel
Synchronization: Externally supplied nStrobe signals
Handshaking: nAck and Busy signals
Signal levels: TTL compatible
Connector: 57RE-40360-830B (DDK) or
equivalent (IEEE 1284 Type B)
Switching between online and offline
TRS
H
L
SPACE (H)
MARK (L)