Specifications

Table Of Contents
Rev. A Disassembly, Assembly, and Adjustment 6-55
TM-J8000/J8000P Technical Manual
Confidential
To install, follow the steps below.
1. Connect the
Tube, waste
and the
Cartridge frame unit
’s tube. Make sure there is no gap
between the two tubes.
Figure 6-84 Connecting the Tube, waste
2. Wearing rubber fingertips, install the
Joint, M6
and
O ring, tube fastener
onto the
Damper
sub-unit
’s tube. Adjust the position of the
O ring, tube fasten
as shown in the illustration.
CAUTION:
Wear rubber fingertips before you touch the tube. Contamination of tip of the tube
could cause ink leakage.
Figure 6-85 Setting the Joint, M6 and O ring, tube fasten
Tube, waste
10 mm ± 1 mm
O ring, tube fastener
Joint, M6