Specifications
Confidential
EPSON
TITLE
SHEET
REVISION
NO.
SHEET
NEXT
86 85
TM-L90
Specification
(STANDARD)
E
DLE DC4 fn d1…d7 (fn = 8)
[Name] Clear buffer(s)
[Format] ASCII DLE DC4 fn d1…d7
Hex 10 14 8 d1…d7
Decimal 16 20 8 d1…d7
[Range] fn = 8
d1 = 1, d2 = 3, d3 = 20, d4 = 1, d5 = 6, d6 = 2, d7 = 8
[Description] • Clears all data stored in the receive buffer and the print buffer.
• Transmits the following three bytes of data.
Hex Decimal Amount of data
Header 37H 55 1 byte
Identifier 25H 37 1 byte
NUL 00H 0 1 byte
• Enters in standard mode.
[Notes] • This command must be inhibited for use in a system using this printer and the EPSON OPOS
/ JavaPOS driver.
• If print data includes a character string containing this command, the printer performs the
command. Users must consider this.
For example: Bit image data accidentally might include a data string with this
command.
• Do not embed this command within another command.
For example: Bit image data might include this command.
• This command is ignored when block data is transmitted.
• When the printer recovers from the paper layout error with
DLE DC4
(fn = 8)
if Msw 8-2 is off,
the automatic paper measurement is done. If the settings for the paper layout are already
stored in the NV memory, these settings are overwritten with the result of the automatic paper
recognition.