Specifications

Confidential
EPSON
TITLE
SHEET
REVISION
NO.
SHEET
NEXT
166 165
TM-L90
Specification
(STANDARD)
E
cn fn
Code Function Description
65
GS ( k
p
L
p
H
cn fn n
Function
265
Specifies the mode for MaxiCode.
80
GS ( k
p
L pH cn fn m
d1...dk
Function
280
Receives and stores data in the symbol
storage area for MaxiCode.
81
GS ( k
p
L pH cn fn m
Function
281
Prints symbol data in the symbol
storage area for MaxiCode.
50
82
GS ( k
p
L pH cn fn m
Function
282
Transmits the size information for the
symbol data in the symbol storage area
for MaxiCode.
"Symbol data" refers to the data (
d1
dk
) received with <Function 080>, <Function 180>, and
<Function 280>.
"Symbol storage area" refers to the range for storing data received with <Function 080>, <Function
180>, and <Function 280> before encoding.
<Function 065> GS ( k p
L
p
H
cn fn n (fn = 65)
[Format] ASCII GS ( k
p
L
p
H
cn fn n
Hex 1D 28 6B p
L
p
H
cn fn n
Decimal 29 40 107 p
L
p
H
cn fn n
[Range] (
p
L
+
p
H
× 256) = 3 (
p
L
= 3,
p
H
= 0)
cn
= 48
fn
= 65
0 n 30
[Default] n = 0
[Description] Sets the number of columns of the data area for PDF417.
n
= 0 specifies automatic processing.
When automatic processing (n = 0) is specified, the number of columns is calculated with
the number of code words based on the range of the printable area.
n 0 sets the number of columns of the data area to n code words.
[Notes] The following data is not included in the number of columns.
Start and stop patterns
Left and right indicator code words