3.16 Radio Field Intensity Check
1) Function
This function prints information about 802.11b I/F wireless communication intensity.
2) Starting radio field intensity check
(1) Open the roll paper cover and turn the power on while pressing the paper FEED button.
(2) Press down the paper FEED button twice.
(3) Close the roll paper cover.
Follow the instructions that are printed out.
NOTE: The radio field intensity check can be performed only in the infrastructure mode. In Ad-hoc
mode, “This feature is not supported in Ad-hoc mode” is printed.
3) Ending radio field intensity check
(1) Press down the power switch to turn the power off.
3.17 Hexadecimal Dumping
1) Hexadecimal dumping function
This function prints the data transmitted from the host computer in hexadecimal numbers and their
corresponding characters.
2) Starting hexadecimal dumping
Open the roll paper cover and turn the power on while pressing the paper FEED button.
3) Hexadecimal dumping operation
After printing "Hexadecimal Dump To terminate..." on the roll paper, the printer prints the
received print data in hexadecimal numbers and their corresponding characters.
NOTES: 1. If a character does not correspond to the data received, the printer prints "."
2. During hexadecimal dumping, any commands other than DLE EOT, DLE ENQ, and DLE
DC4 do not function.
3. Insufficient print data to fill one line can be printed by pressing the paper FEED button.
<Printing example>
Hexadecimal Dump
To terminate hexadecimal dump,
press FEED button three times.
1B 21 00 1B 26 02 40 40 1B 69 . ! . .
&
.
@
@
.i
1B 25 01 1B 63 34 00 1B 30 31 .
%
..c4..01
41 42 43 44 45 46 47 48 49 4A
A
B
C
D
EF
G
HIJ
*** completed ***