Specifications

Confidential
EPSON
TITLE
SHEET
REVISION
NO.
SHEETNEXT
L
TM-U210 series
Specification
(STANDARD)
62 61
6.3 Command Descriptions
HT
[Name] Horizontal tab
[Format] ASCII HT
Hex 09
Decimal 10
[Description] Moves the print position to the next horizontal tab position.
[Notes] This command is valid only when the receive buffer capacity is 40 bytes (when
DIP switch 1-2 is on).
This command is ignored unless the next horizontal tab position has been set.
If the next horizontal tab position is outside the printing area, the printing
position shifts to "printing area width + 1."
Horizontal tab positions are set with ESC D.
The default tab positions are at intervals of 8 characters (columns 9, 17, 25.) for
font B (7 × 9).
[Reference] ESC D
LF
[Name] Print and line feed
[Format] ASCII LF
Hex 0A
Decimal 10
[Description] Prints the data in the print buffer and feeds one line, based on the current line
spacing.
[Note] This command sets the print position to the beginning of the line.
[Reference] ESC 2, ESC 3