User manual

X K 3 1 9 0C 602
Annex A Error Prompt Message
Table A-1 Error Prompt Message Explanation
Error
Prompt
Message
Explanation Handling method
[Error ]
[ 1]
Tare requirement is not met. Tare after getting stable.
[Error ]
[ 2]
Requirement of zero-setting is
not met.
Set zero after getting
stable.
[Error ]
[ 3]
Input parameter exceeds
allowed range.
Input the parameter
correctly.
[Error ]
[ 4]
EEPROM Hardware is
damaged
Replace U15, U16 on main
board
[Error ]
[ 5]
Calibration data is wrong, and
the parameter is initialized.
Recalibrate and reset all
parameters.
[Error ]
[ 6]
Printer wire is not connected
or printer is faulty. Skip by
pressing any key.
Check printer setting or
connection condition
[Error ]
[ 7]
Calibration switch is not
turned on during parameter
calibration or calibration
parameter modification
Turn on calibration switch
before recalibration or
calibration parameter
modification
[Error ]
[ 8]
The loaded weight is too small
or loading weight parameter is
input wrong during calibration
Weight loaded should be
more than 1/5 of max.
weighing limit; the weight
around weighing limit is
better.
[Error ]
[ 9]
Batching value is too small,
startup fails.
Set quantitative scale
parameter correctly
[Error ]
[ 10]
Upper limit sequence of
batching scale is wrong
Set upper limit sequence of
batching scale correctly
[Error ]
[ 11]
Zero-setting scope is exceeded,
zero-setting fails
Check conditions of load
carrier and transducer, or
make recalibration
[Error ]
[ 12]
Zero-setting scope is exceeded,
zero-setting fails
Check conditions of load
carrier and transducer, or
make recalibration
[Error ]
[ 20]
Real time oscillator stopping
vibration
Check, replace crystal Y1,
capacity C21, C22,
resistance R31
[Error ]
X=2~9EEPROM writing is
Check and replace U15 or