Specifications

Rev. I OS and Drivers 4-79
MR Series Technical Reference Manual
MSR Start/End Sentinels (Card Start, Card End, ISO/JIS1 Track 1 Start, ..., JIS2 Start, JIS2
End)
The characters to be prefixed and affixed to the data during the MSR reading are specified.
It is possible to specify this setting for each card and each track. Leave this field blank if no
character is to be added. The default settings are as follows:
Track 1 Start: “%” Track 1 End: “?”
Track 2 Start: “;” Track 2 End: “?”
Track 3 Start: “+” Track 3 End: “?”
Use any of the following special characters:
Carriage return: “\R” or “\r”
Tab: “\T” or “\t”
“\”: “\\”
Others: \xx” Specified directly with xx, representing character codes as
hexadecimals.
Automatic Definition Data Setting Utility for Windows
Function
When this utility is started, the firmware setting is converted into the setting described in the
file, and this utility is terminated.
Startup
The Automatic Definition Data Setting utility (PKLOAD32.EXE) has been copied in the directory
specified in the installation procedure. (If the directory was not specified, this utility has been
copied in the c:\Program Files\MSR Config directory.)
This utility can be started by the following method:
Enter as follows from the MS-DOS prompt:
[Path]PKLOAD32 filename [/n]
File name: This is the pas name of the setting file for specifying the key lock setting
file for Windows or the setting file for this utility. (“***.kyl” file)
/n: When the [n] option is specified, the following dialog box is displayed at
the time of termination.