Operation Manual
41
If you add a MAX! Cube to your system later, you
must reset all devices including the MAX! Wall Ther-
mostat
+
to the initial state prior to teach-in to the
MAX! cube. All settings including your weekly pro-
les are deleted in this process.
10.2. Teaching-in MAX! components at the
MAX! Wall Thermostat
+
(without MAX! Cube)
With the MAX! Wall Thermostat
+
you can set up a sing-
le room solution with up to 8 MAX! Radiator Thermostats
and up to 8 window Sensors. This solution can be operated
without the MAX! Cube. For this purpose teach-in the de-
vices directly to the MAX! Wall Thermostats
+
. These then
take over the settings of the MAX! Wall Thermostat
+
(e.g.
mode, temperature, weekly program).
These single room solutions can be connected only
via a MAX! Cube (see above).
The MAX! Eco Switch cannot be integrated in a sin-
gle room solution. A MAX! Cube is necessary for the
integration of this button.
To teach-in your components proceed as follows:
• First switch the teach-in partner (e.g. the MAX! Radiator
Thermostat) according to teach-in mode.
• Now enable the teach-in mode on the MAX! Wall Ther-
mostat
+
by pressing and holding down the OK button.
• The antenna symboll ( ) is displayed, along with the
teach-in time remaining in seconds. The teach-in time
is 30 seconds.
• After teaching-in was successfull, the MAX! Wall Ther-
mostat
+
switches into the standard operating mode.