Operation Manual

48
In the display, bars for heating phases are displayed
whenever the set temperature for the period is high-
er than the set reduction temperature.
If you want a room (e.g. the bathroom) to also be heated
during lunchtime the programming could look as follows:
Monday - Sunday:
from 00:00 to 06:00 15.0°C
from 06:00 to 09:00 23.0°C
from 09:00 to 12:00 17.0°C
from 12:00 to 14:00 19.0°C
from 14:00 to 18:00 17.0°C
from 18:00 to 22:00 21.0°C
from 22:00 to 23:59 15.0°C
17.2 Switching time/day (t-d) display
The factory setting will show the time on the display. In the
menu the display can be switched to the date.
Open the conguration menu by pressing the menu but-
ton for more than 3 seconds.
Sel ect the t- d menu item wit h the (+) and (-) buttons and
conrm with the OK button.
Now set the format you want to show on the display
(date and time will switch on the display) with the (+)
and (-) buttons.
Conrm setting with the OK button.
17.3 Switching nominal/actual temperature (S-A)
In the factory settings, the display will show the nominal
temperature. In the conguration menu, you can change