Operation Manual

54
tion about taught-in devices.
Before you reset the MAX! wall thermostat to the fac-
tory settings, rst delete the device from the MAX!
software when operating with the MAX! Cube.
Before you teach-in a single room solution with a
MAX! Wall Thermostat
+
to a MAX! Cube, you must
reset all devices to the initial state.
Press the Menu button for more than 3 seconds.
Select the “rES” menu item with the (+) and (-) buttons.
Conrm the setting with the OK button.
The display will show “ACC”, conrm restored factory
settings with the OK button.
If a room control unit is taught-in to the MAX! LAN
Gateway the conguration menu on the device will
be locked. You can still restore the factory settings:
Remove a battery and wait for 60 seconds.
Press and hold down reduce ( ), OK and the - button
simultaneously and insert the battery at the same time
When rESappears on the display, the reset was per-
formed and the buttons can be released.
You can now start to make the setting.