15 Software / Register Settings
After start up (connection to power supply) the transceiver module must be programmed
with the necessary main operating parameters. Configuration is done using the SPI
interface. To achieve the technical data and to ensure the FCC requirements according
FCC Part 15, section 15.249 the register settings must be done after start up.
The necessary software parameter (register settings) are available on request from eQ-3
Limited after conclusion of a non-disclosure agreement.
16 Notes Of Design
Please follow the condition written in this specification.
This product should not be stressed when installed.
Please keep this module away from heat.
The supply voltage should not be exceeding or reverse and should not carry noise
and spikes.
Please keep this product away from other high frequency circuits.
Please follow the condition written in this specification about the control signals of
the module.
17 FCC Information
The RF Transceiver Module eQ-3 TRX916 meets the requirements for modular
transmitter approval as described in FCC Public Notice DA00-1407. To fulfill the
requirements of the FCC rules, the OEM (Original Equipment Manufactor) must pay
attention to the following items.
17.1 FCC ID
The FCC Equipment Authorization for this RF Transceiver Module is identified by
FCC ID: RNT-TRX916
and issued to the grantee
eQ-3 Limited, Hong Kong.