Portable Air Conditioner PAC 122 W OWNER’S MANUAL Please read the instructions carefully and keep for future reference
Equator Appliances undertakes to the consumer/owner to repair or, at our option, to replace any part of this product which proves to be defective in workmanship or material under normal personal, family or household use in USA and Canada, for a period of one year from the date of original purchase.
either 1. Scan the QR Code QR Code 1. Open Smart Phone 2. Open Photo 3. Scan QR Code 4. Click the Link 2. Online at: ApplianceDesk.
! Keep the appliance away from volatile and flammable substances. Keep ventilation openings clear of obstructions. Use a power outlet that is grounded and the correct voltage. When positioning the appliance, ensure the electrical cord is not trapped or damaged. Never unplug the appliance by pulling on the power cord. Grip the plug firmly and pull straight out to remove from wall socket. Ensure that the following is NOT done: Place multiple portable socket-outlets at the rear of the appliance.
Introduction This self-contained compact appliance operates as an air conditioner, air purifier/fan or dehumidifier. It is easily portable with castors and does not require permanent installation.
Accessories 1 3 2 5 4 6 1. Inlet / Exhaust hoses 2. Hose connectors 3. Window kit adapters 4. Window kit 5. Drain Hose 6. Remote control Specifications Table Model Application Area Adapter Input / Output Noise Level PAC 122 W 14126 Ft³/h 296 Sq Ft 115V / 12V 2A 54 dB Net Weight 65 lbs Product Dimensions (HxWxD) 30" x 18.
Placement 20 inches space around unit Place the unit on a firm, level surface in an area with at least 20 inches (50 cm) of free space around it to allow for proper air circulation. If tipped more than 45°, allow the unit to stand upright for at least 24 hours before starting it. It allows compressor to stabilize. Ensure the unit is not operated in close proximity to walls, curtains, or other objects that may block air inlet and outlet. Keep the air inlet and outlet free of obstacles.
Installation Attaching the Hoses This is an advanced portable AC where there are 2 hoses: The Right Hose brings fresh air into the unit. The Left Hose blows hot exhaust air to the outdoors. Do not replace or extend the hoses which will result in decreased efficiency, or even worse shut down the unit due to low back pressure. Follow these steps to install both hoses: Step 1: Connect the hose connector to one end of the hose. Step 2: Connect the windows kit adapter to the other end of the hose.
Step 4: Close your window to secure the kit in place. To hold the window kit firmly in place, secure the window kit with duct tape if required. It is recommended that the gap between the adapter and the sides of the window should be sealed off for maximum efficiency. Step 5: Attach the hose connector to the window kit adapter. Step 6: Adjust the length of the flexible hose and avoid bends in the hose. Then place the appliance near an electrical outlet, and plug it in.
Operation CONTROL PANEL AND DISPLAY 11 10 8 3 Cool Dry Air Power Timer 9 7 6 5 4 2 1 1 Power Press to switch the unit on or off. 2 Mode Press to switch the operation mode between Cool Dry and Air (Air Purifier/Fan). 3 Mode Displays the Mode: Cool Indicator 4 Sleep Press to turn Sleep 5 Down Press to decrease the desired temperature or timer setting. 6 Swing Select the air flow. 7 Speed Press to select the fan speed: High, Medium or Low.
Operation Start-up and Shutdown Press Power to turn the unit on or off. Air (Air Purifier/Fan) mode is the default. Press Mode button to select the desired operation mode. The unit has three operation modes: Cool, Dry and Air (Air Purifier/Fan). Cool - Air Conditioner Press Mode button repeatedly until the Cool icon lights up. Press Up/Down arrows to adjust the temperature which is displayed on the screen. The temperature can be set between 60.8O F and 89.6OF Press Speed button to select the desired fan speed.
Dehumidifier Drainage When using the Dehumidifier, water collects in the unit and needs to be drained either continuously or when it gets full. Water can be drained either from the Upper Drain Outlet or from the Lower Drain Outlet. For continuous draining, while the unit is operating as a Dehumidifier: Securely connect the drain hose provided to the unit at the Upper Drain Outlet. Place the other end of the drain hose into a drain pan or bucket.
Sleep mode Press the Sleep button when the unit is in Cool mode. After 1 hour the preset temperature is increased by one degree, after another hour the preset temperature will again be increased by one degree. Timer (1 hour – 24 hours) Press the Timer button and the Up and Down arrows to select how long (hours) the unit is set to operate. Remote Control The selections on the Control Panel can also be made on the Remote Control device.
If not continuously drained, the unit will need to be drained manually. Note: When the water collection tank in the unit gets full, it will stop working and an error code of “Ft” will be displayed on the Control Panel. Turn off the appliance and unplug it. If the unit needs to be moved, do it carefully to prevent water from spilling. Securely connect the drain hose provided to the unit at the Lower Drain Outlet. Place the other end of the drain hose into a drain pan below the Lower Drain Outlet.
Troubleshooting Problem Possible Cause Solution The unit is not operating Check the power connection Check if water tank in unit is full Insert the power cord securely into the wall outlet Empty the water tank by removing the drain plug Check the room temperature The operating temperature range is 41-95ºF (5-35℃) Check the air filter for debris Replace the air filter as necessary Check if the air duct is blocked Clear the obstacle Check if the room door or window is open Keep the door and windows
Error Codes Error Codes E0 Communication faults between main PCB and display PCB Check the wire harness of the display PCB for damage E1 Ambient temperature sensor failure Check connection or replace it. Clean or replace the temperature sensor E2 Coil temperature sensor failures Check connection or replace it.