Installation Instructions The Induction Cook tops must connect to a separate, grounded wire, single phase, AC Only electrical supply with their own circuit breaker. These appliances must be installed in accordance with National Electrical Codes, as well as all state, municipal and local codes. This appliance must be supplied with the proper voltage and frequency and amperage, which is protected by a properly sized circuit breaker or time delay fuse.
Installation Instructions If 4-Wire Cable from Home Power Supply IMPORTANT: Use the 4-wire cable from Home Power Supply where local codes do not allow grounding through neutral.
Installation Instructions Installation — 30" (76.2cm) Model: BIC 304 oy Cook top Dimensions (Top) Width B. Depth C. Height “4. *DO NOT obstruct these areas. Junction box IMPORTANT: For perfect Vent: ventilation, provide a vent of under the counter top, in the front of the cabinet and in the back of the cabinet. The ventilation opening is to Min.: 19.87" (508) extend the full length of the Max.: 20.06" (510) cook top cutout. 45" (114) Front Min.: 28.56" (750) Max.: 29.
Installation Instructions a A CAUTION 2.75" (70mm) distance — I oven. 2.75" (70mm) It Is very Important to keep between the cook top and the OVEN Note: Deputation oven and cook top. divider between the Spacer Graphic Profile Counter top Do not remove spacer After Installation 1. Remove all the stickers and items from the top of the cook top surface. 2. Clean cook top before use. Dry with a soft cloth. 3. Read Using The Cook top. 4. Turn on the power to the cook top. 5.