Installation Guide

14
BUILT-IN, RECESSED, CLOSET AND ALCOVE INSTALLATION
MINIMUM CLEARANCE OTHER THAN ALCOVE OR CLOSET INSTALATION
2" 2"
3" 3"
3" 3"
Maximum Length of
Exhaust Duct is 10 feet
Minimum clearances to combustible surfaces: 2" (5 cm) clearance both sides and 3" (7.5 cm) rear.
The Combo Washer-Dryer may be installed in a built-in, recessed area, closet or alcove.
The installation spacing is in inches and is the minimum acceptable.
Other installation must use the minimum dimension indicated.
Minimum clearance between dryer cabinet and adjustment walls are: 2" either side and 3" front and rear.
Minimum vertical space from floor to overhead cabinets, etc. is 52" (132 cm).
Closet door must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of open
area equally distributed. If this closet contains both washer and a dryer, doors must contain a minimum
120 sq. in. of open area equally distributed.
No other fuel-burning appliance shall be installed in the same closet with dryer.
Additional clearances for wall, door and floor molding may be required.
Additional space is needed when an external exhaust elbow is used.
NOTE: If a door is installed that potentially encloses the unit while running, the door must allow for a
minimum of 20 sq. in. of air free movement. There must also be a 1" additional space in front of the
unit to the closed door and 1" from the back of the unit to the wall. Additional spacing should be
considered for easy installation, servicing and compliance with all applicable local, state and federal
codes.
Ventless Vented