Installation Guide

24
DIAGNOSTIC MENU
Door open
Drain failure
Water inlet failure
Water overfill
Motor failure
Washing heater failure
Dryer Malfunction
Dryer Malfunction
Water level failure
Dryer Malfunction
Dryer Malfunction
Dryer Malfunction
Communication between
display & electronic module
Door Switch
Drain Pump
Inlet Valves
Pressure Switch
Motor
+Electronic Module
Washing heater
Temp. sensor
(@rear-bottom of tub)
Temp. sensor
(@front of heater housing)
Water level sensor
Temp. sensor
(near the blow fan motor)
Fan Motor
Dying heater
Communication
Cable
E1
E2
E3
E4
E5
E7
E8
E9
E10
E11
E12
E13
E16
Code Description Component