ELECTRICAL CONNECTION
• THIS ICE MAKER SHOULD BE PROPERLY GROUNDED FOR YOUR SAFETY. THE POWER
CORD OF THIS ICE MAKER IS EQUIPPED WITH A THREE-PRONG PLUG WHICH MATES
WITH STANDARD THREE PRONG WALL OUTLETS TO MINIMIZE THE POSSIBILITY OF
ELECTRICAL SHOCK.
• DO
NOT UNDER ANY CIRCUMSTANCES CUT OR REMOVE THE THIRD GROUND PRONG
FROM THE POWER CORD SUPPLIED.
• DO
NOT USE AN EXTENSION CORD TO CONNECT POWER TO THE UNIT.
• DO
NOT USE A TWO-PRONG GROUNDING ADAPTER.
• IF
YOU ONLY HAVE A TWO-PRONG WALL RECEPTACLE, CONTACT A QUALIFIED
ELECTRICIAN TO HAVE IT REPLACED WITH A 3-PRONG RECEPTACLE IN ACCORDANCE
WITH APPLICABLE ELECTRICAL CODES.
• THIS
ICE MAKER REQUIRES A STANDARD 115 VOLTS A.C. 60HZ ELECTRICAL OUTLET
WITH THREE-PRONG GROUND.
• THE
CORD SHOULD BE SECURED BEHIND THE ICE MAKER AND NOT LEFT EXPOSED OR
LOOSE.
EXTENSION CORD
BECAUSE OF POTENTIAL SAFETY HAZARDS, THIS APPLIANCE IS NOT RECOMMENDED FOR
USE WITH AN EXTENSION CORD. HOWEVER, IF YOU MUST USE AN EXTENSION CORD, USE
ONLY A UL/CUL-LISTED, 3-WIRE GROUNDING TYPE APPLIANCE EXTENSION CORD WITH A
GROUNDING TYPE PLUG AND OUTLET. THE ELECTRICAL RATING OF THE CORD MUST BE
115 VOLTS AND AT LEAST 10 AMPS.
¾ CONNECTING
THE WATER SUPPLY
• ALL
THE NECESSARY HARDWARE IS NOT PROVIDED (AS THE PLUMBING FIXTURES AT
THE INSTALLATION POINT MAY DIFFER) FOR INSTALLATION SO IT IS NECESSARY TO
HIRE A PROFESSIONAL LICENSED PLUMBER TO COMPLETE THE INSTALLATION.
• CONNECT
TUBING (SUPPLIED WITH UNIT) TO THE NEAREST COLD WATER SOURCE.
HAVE SUFFICIENT TUBING TO ALLOW UNIT TO BE MOVED FREELY
FOR CLEANING AND SERVICE. ALSO MAKE SURE THAT THE TUBING
IS NOT PINCHED OR DAMAGED DURING TRANSPORTATION AND/OR
INSTALLATION.
• POSITION
UNIT TO ALLOW AIRFLOW THROUGH THE FRONT GRILL
(SEE FIGURE 1).
• WIPE
THE INSIDE OF UNIT AND ICE BUCKET WITH A DAMP CLOTH.
DANGER or WARNING:
1. Risk of child entrapment. Before you throw away your old refrigerator or freezer:
- Take off doors.
- Leave the shelves in place so that children may not easily climb inside.”
2. Do not use extension cords.
aWARNINGa
IMPROPER USE OF THE GROUNDED PLUG CAN RESULT IN THE RISK OF ELECTRICAL
SHOCK. IF THE POWER CORD IS DAMAGED, HAVE IT REPLACED BY AN AUTHORIZED
SERVICER.
FIGURE 1
aWARNINGa
IMPROPER WATER LINE CONNECTION MAY RESULT IN FLOODING
YOU MUST USE A LICENSED PLUMBER
REVIEW STATE AND LOCAL PLUMBING CODES BEFORE INSTALLATION