Operation Guide

Table Of Contents
Command
Name
Command Format Response Format Explanation
RF baud
rate setting
baud protocol
type\r\n
e.g.: baud 9600\r\n
Indicate setting up
the current radio RF
baud rate as 9600
\r\nPROGRAMMED
OK\r\n>
Indicate the current
radio RF baud rate is
written successfully
Operating
mode query
mode\r\n
\r\nMODE operating
mode\r\n>
e.g.: \r\nMODE
DUPLEX\r\n>
Indicate the current
radio operating mode
is
transmitting-receiving
One space character is
between “MODE” and
“operating mode” for
separation; “operating
mode” has 8 characters in
length, if the operating mode
currently displayed has less
than 8 characters in length,
use space characters to fill;
for example, for operating
mode of duplex, there are
only 6 characters, 2 space
characters are additionally
needed;
Operating
mode setting
Mode operating
mode\r\n
e.g.: mode duplex\r\n
Indicate setting up
the current radio
operating mode as
transmitting-receiving
\r\nPROGRAMMED
OK\r\n>
Indicate the current
radio operating mode
is written successfully
The operating modes
supported are:
DUPLEX
(transmitting-receiving),
TXONLY (single
transmitting), RXONLY
(single receiving), RPT
(radio relaying mode),
NETRPT (network relaying
mode)
Transmitting
power query
pwr\r\n
\r\nPWR power
level\r\n>
e.g.: \r\nPWR L\r\n>
Indicate the current
radio transmitting
power is 5W
The corresponding relations
among power levels:
H-28W;M-22W;L3-5W;
One space character is
between PWR” and “power
level” for separation;
“power level” has 1
characters in length
Transmitting
power
setting
pwr power level\r\n
e.g.: pwr L\r\n
Indicate setting up
the current radio
transmitting power as
5W
\r\nPROGRAMMED
OK\r\n>
Indicate the current
radio transmitting
power is written
successfully
Serial port
baud rate
query
sbaud\r\n
\r\nSBAUD serial port
baud rate\r\n>
e.g.: \r\nSBAUD
115200\r\n>
Indicate the current
radio serial port baud
The list of serial port baud
rates supported is shown as
below:
9600
19200,38400,57600,115200;
One space character is