User guide
Table Of Contents
- Presentation
- Warning
- Copyright
- 1 References
- 2 Packaging
- 3 General presentation
- 4 Characteristics and Services
- 5 Use of the modem
- 5.1 Starting with the modem
- 5.2 Specific recommendations for the use of the modem in vehicles
- 5.3 GSM led of the modem
- 5.4 Echo function of AT commands deactivated
- 5.5 Checking the quality of the GSM reception signal
- 5.6 Verification of PIN code
- 5.7 Verification of modem registration on GSM network
- 5.8 Verification of modem registration on GPRS network
- 5.9 Verification of internal voltages of the modem
- 5.10 Main AT commands (HAYES)
- 5.11 Turning OFF the modem
- 5.12 Updating procedure of the modem
- 6 Trouble Shooting
- 7 Functional description
- 8 Technical characteristics
- 8.1 Mechanical characteristics
- 8.2 Electrical characteristics
- 8.3 Environmental characteristics
- 8.4 Standards/Conformities
- 9 Security recommendations
- 10 Recommended accessories
- 11 Client support
EG_GenPro25e_1055_UG_000_UK Page 24 / 66
Descriptions and non-contractual illustrations in this document are given as an indication only.
ERCO & GENER reserves the right to make any modification.
Dct_427_01
5.1.3 Checking the communication with the modem
5.1.3.1 Without library
The GenPro 25e does not contain any library, it will return the menu of the Bootloader.
Connect the RS232 link between the DTE (the COM port) and the modem (DCE).
Configure the RS232 port of the DTE as follows:
Bits per second ..... : 115 200 bps,
Data Bits ................ : 8,
Parity ..................... : None,
Stop Bits ................ : 1,
Flow control ........... : material.
Use a communication software like Windows HyperTerminal ®.
Menu by default when there is no library inside the equipment (example of display)
Bootloader V4.11 GP25 UA Gener Ublox (HWF7 rev C)
GSM voltage = 3655 mV
1 - Update application
2 - Erase objects
M - GSM direct access (external supply required)
A - Advanced
P - Power off
E - Exit
In this configuration, the led is OFF.
In the case where no communication can be established with the modem:
Check the RS232 connection between the DTE and the modem (DCE),
Check the configuration of the COM port of the DTE.
5.1.3.2 With transparent mode application
The GenPro 25e contains the transparent mode application; it is waiting for a command.
Connect the link RS232 between the DTE (COM port) and the modem (DCE).
Set the RS232 port of the DTE as follows:
Bits per second ..... : 115 200 bps,
Data Bits ................ : 8,
Parity ..................... : none,
Stop Bits ................ : 1,
Flow control ........... : material.
Use a communication software like Windows HyperTerminal ®.
Send the AT command. The modem returns OK. For more precision about the commands, see the