5.9 Verification of internal voltages of the modem
The modem contains the application EasePro V2.xx (see the documents
EG_EasePro_V2.xx_CL_yyy_UK.pdf)
Two commands allow reading the internal voltages of the modem.
The input of the DC/DC converter +V
DC
The battery voltage if this option is present +V
INTERNE
Figure 17 : Internal voltages of the modem
5.9.1 Reading the power supply voltage +V
DC
The command AT+EGADC=0 allows to read the power supply voltage +V
DC
of the modem. This voltage is
measured in mV
DC
.
Check the conversion correction factors with the command AT+EGADC=0,0,0
They must be +EGADC: 0,987,100,"0"
If this is not the case, enter them with the command AT+EGADC=0,987,100,0 These parameters are
memorized.
Example:
AT+EGADC=0
+EGADC: 0, 11939
OK
For more information about the AT commands, see the document "EG_EasePro_V2.xx_CL_yyy_UK.pdf"