8.2.5.2 Output (S1)
Table 37 : Characteristics of open-collector output
Characteristics Symbols Conditions Max. Unit
Max. voltage V
CE0
Transmitter open 48 V
DC
Max. voltage V
CES
V
BE
= 0 V 48 V
DC
Collector current I
C
0.5 A
Saturation voltage V
CEsat
I
C
= 500 mA 1.3 V
Dissipation P
Ttot
T
amb
25 °C, T
j
= 110 °C 0.78 W
Figure 27 : Electrical scheme of the output
No protection is provided. The user must respect the values of the table above.
8.2.5.3 Analog input - ANA1 (0 - 10V) on INPUT 2
As an option, it is possible to have an analog input instead of the opto-coupled input I2.
This analog input allows to do a voltage measure (contact us).
Table 38 : Characteristics of the analog input option in voltage
Characteristics Symbols Conditions Min. Typ. Max. Unit
Analog input ANA1 12 V
dc
Conversion range 6.5 V +V
DC
32V 0.010 10.33 V
dc
Polarization current From 10 mV to 10.33 V 1.34 350 µA
dc
Figure 28 : Internal electrical scheme of the option Analog Input 1
The integrator has the responsibility to protect the input from electric disturbances and to
respect the values of the functioning parameters.