User Manual
Table Of Contents
- toc
- 1 Introduction
- 2 Product Overview
- 3 Dimensions
- Weight
- Colour
- 4 Space Requirements
- Space above the RBS Cabinet
- Layout for RBS Cabinets
- Earthquake Requirements
- Footprint
- 5 Environment
- 6 Hardware Units
- 6.1 RBS 2206 Standard Hardware Units
- ACCU-01
- CDU
- CXU-10
- DCCU-01
- dTRU
- DXU-21
- FCU
- IDM-01
- PSU
- DC Filter-01
- 6.2 RBS 2206 V2 Standard Hardware Units
- ACCU-11
- CDU
- CXU-10
- DCCU-11
- DCCU-13
- dTRU
- DXU-23
- IDM-11
- PSU
- 6.3 Optional Hardware Units
- ASU-01
- Bias Injector
- BBS
- ddTMA
- DXX
- DF
- ESB
- HCU
- 19-inch Space for Optional Equipment
- OXU
- Splitter
- TMA-CM-01
- TMA-CM-02
- 7 Interfaces
- 8 Power System
- 9 Transmission
- Overvoltage Protection Modules
- Optional Transmission Equipment
- 10 External Alarms
- 11 Standards, Regulations and Dependability
RBS Product Description
RBS 2206 +24 V DC Fuses
Table 13 Fuse Specifications
Minimum for Safe
Function
Recommended for
Maximum Selectivity
Maximum Allowed
Fuse Rating
1 × 160 A
(1)
1 × 200 A 1 × 250 A
(1) Can be used when no transmission or optional equipment is installed.
RBS 2206 V2 +24 V DC Fuses
Table 14 Fuse Specifications
Minimum for Safe
Function
Recommended for
Maximum Selectivity
Maximum Allowed
Fuse Rating
1 × 160 A 1 × 200 A 1 × 300 A
8.3
0
48 V DC to
0
60 V DC Power
Table 15 Requirements
Characteristic
Description
Nominal
0
48 or
0
60 V DC
Range
0
40.0 to
0
72.0 V DC
Non-destructive range +0 to
0
80 V DC
Inrush current 200 A (0.1–5 ms)
RBS 2206
0
48 V DC to
0
60 V DC Fuses
Table 16 Fuse Specifications
Minimum for Safe
Function
Recommended for
Maximum Selectivity
Maximum Allowed
Fuse Rating
4 × 32 A 4 × 35 A 4 × 40 A
RBS 2206 V2
0
48 V DC to
0
60 V DC Fuses
Table 17 Fuse Specifications
Minimum for Safe
Function
Recommended for
Maximum Selectivity
Maximum Allowed
Fuse Rating
3 × 45 A 3 × 50 A 3 × 50 A
28 19/1551-LZA 701 0001 Uen PG1 | 2010-10-08