User Manual
Table Of Contents
- toc
- 1 Introduction
- 2 Product Overview
- 3 Dimensions
- Weight
- Colour
- 4 Space Requirements
- Space above the RBS Cabinet
- Layout for RBS Cabinets
- Earthquake Requirements
- Footprint
- 5 Environment
- 6 Hardware Units
- 6.1 RBS 2206 Standard Hardware Units
- ACCU-01
- CDU
- CXU-10
- DCCU-01
- dTRU
- DXU-21
- FCU
- IDM-01
- PSU
- DC Filter-01
- 6.2 RBS 2206 V2 Standard Hardware Units
- ACCU-11
- CDU
- CXU-10
- DCCU-11
- DCCU-13
- dTRU
- DXU-23
- IDM-11
- PSU
- 6.3 Optional Hardware Units
- ASU-01
- Bias Injector
- BBS
- ddTMA
- DXX
- DF
- ESB
- HCU
- 19-inch Space for Optional Equipment
- OXU
- Splitter
- TMA-CM-01
- TMA-CM-02
- 7 Interfaces
- 8 Power System
- 9 Transmission
- Overvoltage Protection Modules
- Optional Transmission Equipment
- 10 External Alarms
- 11 Standards, Regulations and Dependability
Transmission
8.4 Power Consumption
The power consumption figures shown in the table below are for dimensioning
cables and fuses. The figures in the table have been rounded off.
Table 18 Power Consumption RBS 2206
Power Supply Voltage
RBS Cabinet
(Fully Equipped)
120–250 V AC +24 V DC
0
48 V DC
Maximum Powe
r Consumption
3.9 / 5.7 kW
(1)
3.2 kW 3.8 kW
(1) Power consumption during maximum battery charging.
The RBS can supply transmission equipment with +24 V DC. The maximum
power output is 250 W.
Table 19 Power Consumption RBS 2206 V2
Power Supply Voltage
RBS Cabinet
(Fully Equipped)
120–127 V
AC
200–250 V
AC
+24 V DC
0
48 V DC
Maximum Power
Consumption
3.3 / 4.1
kW
(1)
3.2 / 5.1 kW 3.0 kW 3.4 kW
(1) Power consumption during maximum battery charging.
9 Transmission
The RBS is normally connected to a DF for transmission. Four transmission
cables are connected to the ports on the front of the DXU. The RBS supports
two transmission standards:
• T1 1.5 Mbit/s, 100
,
• E1 2 Mbit/s, 75
• E1 2 Mbit/s, 120
2919/1551-LZA 701 0001 Uen PG1 | 2010-10-08