Table 25 Reading and Checking IDB
Check that the following parameters are correct: OK
Transmission interface
Cabinet configuration(s)
Antenna sector configuration(s)
5. If the IDB parameters in the table above need to be set, see Section 7.6.3
Creating IDB on page 109.
If the IDB parameters above are correct, set the following applicable
site-specific IDB parameters:
Alarm inlets (external alarms)
ALNA/TMA parameters
Delay
GPS parameters
Hardware Information
Loss
RBS Identity
Transmission (PCM) parameters
TEI value for IXU
TNOM parameters
7.6.3 Creating IDB
This section describes how to define the configuration setup in the OMT. The
OMT can detect the cabinet setup if the Detected HW Information checkbox in
the Create IDB window is selected.
Note: The OMT must be logically connected to the RBS to be able to retrieve
the HW information.
Defining Transmission Interface
1. On the RBS 2000 menu, ensure that the OMT is logically disconnected
from the RBS.
2. On the Configuration menu, click Create IDB to open the Create IDB
window.
3. Select the transmission interface.