4. Repeat steps 2 to 3 for all applicable HW units.
5. Click Close when finished.
7.6.9 Defining Loss
This section describes how to define the Total Feeder Attenuation.
1. On the Configuration menu, click Define and Loss to open the Define
Loss window.
2. Select the appropriate feeder cable (for example, FEED_RXA 0) and click
Run.
3. In the Define Loss window, enter the Total Feeder Attenuation from the test
record for Antenna System Tests and click OK. The OMT has default values
for the RRU to RXBP RX cables.
4. Repeat steps 2 to 3 for each RX and TX feeder used.
5. Close the Define Loss window when finished.
7.6.10 Defining RBS Identity
This section describes how to define the RBS Identity.
1. In the Configuration menu, select Define and RBS Identity to open the
Define RBS Identity window.
2. In the RBS name field, enter the unique RBS name.
3. In the RBS description field, enter the site name or the location of the site
(maximum of 100 characters).
4. Click OK.
7.6.11 Defining Transmission Interface E1, 75
This section describes how to define the PCM parameters for transmission
interface E1, 75 .
1. On the Configuration menu, click Define and PCM.
2. Set the parameters according to the table and instructions below.
3. Click OK when all parameters are set.
1
16
E