Reference Manual

EMC Capabilities
Criteria CT for transmitter units
Criteria CR for receiver units
Table 35 Immunity of 50/60 Hz magnetic fields
Basic standard EN 61000-4-8
Test level 10 A/m, 50/60 Hz
Performance Criteria A
4.3.8 Electro-static Discharges
Table 36 Immunity of enclosure port
Basic standard EN 61000-4-2
Test level Air discharges: 15 kV
Contact discharges: 8 kV
Performance Criteria B
Limit standard ETS 300 342-2
Test level Air discharges: 8 kV
Contact discharges: 4 kV.
Performance Criteria A for a complete system
Criteria TT for transmitter units
Criteria TR for receiver units