RBS 2308 and RBS 2309 User’s Guide
Attenuation, dB/m (CABLE LOSS)
Feeder Type
Andrew
Velocity
Factor
(PROP
VEL)
GSM
800
GSM
900
GSM
1800
GSM 1900
3/8-in. FSJ2 (flex)
0.83 0.121 0.127 0.185 0.191
1/2-in. LDF4
0.88 0.066 0.069 0.101 0.104
1/2–in. FSJ4 (flex)
0.81 0.107 0.112 0.166 0.171
7/8-in. LDF5
0.89 0.037 0.039 0.058 0.060
1 1/4-in. LDF6
0.89 0.027 0.028 0.042 0.043
1 5/8-in. LDF7
0.88 0.022 0.023 0.035 0.036
Note: If the cable type is not found in the table above, the values must be
taken from the manufacturer’s specifications.
6.3 Performing DTF Tests
The purpose of the Distance To Fault (DTF) test is to verify that there are no
bad connections or other faults (for example sharp bends) in the feeder system.
It also measures the length of the feeder system to be used in the feeder
attenuation calculation.
It is recommended to perform the DTF tests during the installation phase,
before the antennas are connected.
6.3.1 Connecting DTF Test Setup
This section contains test setups and information about how to connect the test
equipment for the DTF tests.
1. Connect the 50 standard load to the antenna connector of the feeder.
See figure below.
2. Connect the test equipment to the RBS jumper. See figure below.