User's Manual Part 2

RBS 2308 and RBS 2309 User’s Guide
6. Observe the trace i
n the frequency range according to the table below.
Table 22 Measurement Frequency Range for Passive Antenna Systems
System Start Freq. (MHz) Stop Freq. (MHz)
GSM 800
824 894
E-GSM 900
880 960
P-GSM 900
890 960
GSM 1800
1710 1880
GSM 1900
1850 1990
7. Check that no SWR levels are over 1.4 (= 15.6 dB RL) or 1.5 (= 14 dB RL)
for low loss feeders, between the frequencies stated in the table above. For
conversion between VSWR and Return Loss see Table 24 on page 107.
Enter the
test result in the test record. For examples of approved and
unapproved waveforms, see figures below.
8. Create a unique trace name in accordance with Section 6.8 Naming an
SWR Measurement on page 103. Save the measurement by pressing
the SAVE DISPLAY key. Type in the trace name using the alphanumeric
soft keys, and press ENTER.
9. Repeat the SWR test for each feeder on the site.
Example of an Acceptable SWR Measurement
P010265A
CAL ON LIM ON 259 POINTS RECALL
2.00
M1
1000.0FREQ (MHz)800.0
1.00
M2
M3
M4
M3=OFFM1:1.03,889.9MHz
M4=OFFM2:1.19,959.7MHz
ALL
OFF
SWR ANTENNA 900
1.4
Figure 44 Example of an Acceptable SWR Measurement
102
EN/LZT 720 0027 Uen R8A 2006-06-27