User's Manual Part 2

RBS 2308 and RBS 2309 User’s Guide
Example of an Unacceptable SWR Measurement
P010277A
CAL ON LIM ON 259 POINTS RECALL
2.00
M1
1000.0FREQ (MHz)800.0
1.00
M2
M3
M4
M3=OFFM1:1.03,889.9MHz
M4=OFFM2:1.19,959.7MHz
ALL
OFF
SWR ANTENNA 900
1.4
Figure 45 Example of an Unacceptable SWR Measurement
6.8 Naming an SWR Measurement
This section describes how to give the measurement a unique name traceable
to the correct antenna system on the correct site.
1. Find the cell ID in the Site Installation Documentation.
2. Read the label on the jumper measured.
3. Combine the measurement type, cell ID, and label text (a unique name
with a maximum of 16 characters).
The following example illustrates these steps: Site Installation Documentation
1. The cell ID found in the Site Installation
Documentation is "SOF007_A".
2. The text on the feeder label is "Cell A: DX1".
3. The type of measurement is SWR, so the name of
the measurement is "SWRSOF007ADX1".
Example 4 Naming an SWR Measurement
1
03
EN
/LZT 720 0027 Uen R8A 2006-06-27