RBS 2308 and RBS 2309 User’s Guide
6.9.2 Making a Test Recor
d Supplement
The figure below is
an example of a printout from the Site Master Software
Tools. This should
be added as a supplement to the test protocol, and included
in the Site Instal
lation Documentation.
50454035302520151050
Resolution: 259
BiasTee: OFF
Date: 02/23/2001
Model: S331B
Distance (0,0 - 50,0m)
CAL: ON(COAX)
Output Power: -30,00 dBm
Time: 04:18:45
Serial#: 00028071
1,200
1,175
1,150
1,125
1,100
1,075
1,050
1,025
1,000
Limit: 1,05
M1
M2
Distance To Fault
DTFSOF007ADX1
M1: 1,014 @ 2,132m M2: 1,008 @ 40,698m
VSWR
P007955A
Figure 47 Example of a DTF Measurement Plot
After saving all test results in the Site Master, the test results must be
transferred to a PC using the serial cable and the Site Master Software Tools.
See the instructions below. For further instructions, see:
Anritsu Site Master User’s Guide
1. Connect the Site Master to the PC’s serial port, using the serial cable.
2. Start the Site Master Software Tools on the PC.
3. Click the Start Plot Capture button in the Site Master Software Tools.
4. Select the desired plots from the Plots Download dialog box and click OK.
5. Save the plots to the PC.
6. Print the plots from the Site Master Software Tools, and insert them in
the Site Installation Documentation.