7.6.1 Creating IDB
This section describes how to define the configuration setup in the OMT.
Defining Transmission Interface
1. On the RBS 2000 menu, select Disconnect to disconnect the OMT
logically from the RBS.
2. On the Configuration menu, select Create IDB to open the Create IDB
window.
3. Select the transmission interface.
Defining Cabinet Setup
1. To add cabinets to the Cabinet Setup box, click New to open the Define
Setup for Cabinet window.
2. In the Cabinet Type box, select the RBS type:
2308
2309
Note: If IP is selected as the transmission interface, then 2308 is automatically
selected in this step and the Define Cabinet Options window is opened.
3. In the Define Cabinet Options window, select the applicable master cabinet
configuration and click OK:
–IXU
–IXU/RRU
4. Select the power system used:
230/115 V AC, no backup
230/115 V AC, external battery
48 V DC
5. If an RRU is present in the cabinet, select the climate system used:
Cooling by convection
Fan unit