User's Manual Part 2

RBS 2308 and RBS 2309 User’s Guide
4. Select IDB and click Run. Check the parameters listed in the table below.
Table 29 Reading and Checking IDB
Check that the following parameters are correct: OK
Transmission interface
Cabinet configuration (s)
Antenna sector configuration(s)
5. If the IDB parameters in the table above need to be set, see Section 7.6.1
on page 116.
If the IDB parameters above are correct, set the following applicable
site-specific IDB parameters:
Alarm inlets (external alarms)
•Delay
GPS parameters (does not apply to BSS R9 software)
Hardware information
Loss
RBS identity
Transmission (PCM) parameters
TEIvaluefortheIXU
TNOM parameters
6. On the RBS 2000 menu, select Disconnect to disconnect the OMT
logically from the RBS.
7.6.4 Opening IDB from File
This section describes how to open a saved IDB file from the disk.
1. Start the OMT.
2. On the Configuration menu, select Open IDB.
3. Locate and select the saved IDB file to be opened.
4. Click Open in the Open IDB dialog box to open the saved IDB file.
7.6.5 Defining External Alarms
This section describes how to define the external alarms, if applicable.
1
19
EN
/LZT 720 0027 Uen R8A 2006-06-27