User's Manual Part 2

RBS 2308 and RBS 2309 User’s Guide
Table 46 PCM Parameters Settings for Transmission Interface T1, Long
Haul Automatically
PCM Parameter Setting
Transmission Interface DS1(T1)
Network Topology
See Site Installation Documentation.
Sync Source See Site Installation Docume
ntation
LBO A
LBO B
LBO C
LBO D
See instructions below
FDL Use
See Site Installation Documentation
The instructions below describe how to automatically set the PCM parameters.
For RBS 1 only:
1. Set LBO A (C) to “Long h. ALBO, <value of the maximum input signal
level> dB”.
2. If stand alone, set unused ports to “Short h., 0 133 feet”. Unused ports
are always set to “Short h., 0 133 feet”.
The RBS automatically sets the correct value in the IDB when the IDB
is installed.
Note: The following instructions apply only to m ultidrop.
If multidrop is used, the line attenuation for RBS 1 must be measured according
to the instructions below.
For RBS 1:
1. Set LBO B (D) to “Long h., 0 dB”. Used B (D) ports in multidrop are always
set to “Long h., 0 dB”
2. On the RBS 2000 menu, click Connect.
3. On the Configuration menu, click Install IDB.
The RBS will automatically set the correct value in the IDB.
The RBS remains in Local mode after the IDB has been installed.
4. On the Maintenance menu, click Monitor.
5. In the Available monitors box, select “Line Attenuation
forPCM-A”(C)and
click to add “PCM” i n the Monitors to start box. See figur
e below.
1
35
EN
/LZT 720 0027 Uen R8A 2006-06-27