User's Manual Part 2

RBS 2308 and RBS 2309 User’s Guide
P015758A
Resetting the
Configuration
Attaching the
Local Terminal
Configuring for
Remote Operation
Checking Status
Verifying Remote
Operation
Performing Concluding
Routines
Figure 62 Work Process
8.3 Procedure
This section describes how to put the PSTU into remote operation.
For more information on command attributes, examples, responses, and
alarms, see section Documentation above.
8.3.1 Attaching the Local Terminal
This section describes how to attach the local terminal to the PSTU.
1.
Start the local terminal and ensure that the communication parameters
for the terminal are c orrect. See table below.
Table 53 Local Terminal Parameters
Parameter Value
Bits per second 115200
Data bits 8
Parity None
Stop bits
1
Flow c ontro l None
1
51
EN
/LZT 720 0027 Uen R8A 2006-06-27