User's Manual Part 2

RBS 2308 and RBS 2309 User’s Guide
The PSTU restart ta
kes a few minutes. The status of the PSTU indicators
is shown in the tabl
e below.
Table 54 Indicator
Status
Status
Indicator
During Restart
After Restart
Operational Off
Flashing slowly: 0 .5 Hz
(local operation mode)
Fault Red
(first few second
s)
Off
8.3.3 Configuring for Remote Operation
This section describes how to connect the PSTU to the IP network and
configure the PSTU for remote operation.
1.
Connect the correct Ethernet cable for IP transmission. See figures
below. Optical Ethernet connections are showninFigure64onpage
155, and electrical Ethernet connections are showninFigure65on
page 156.
For instructions on passing the Ethernet cables through the most
suitable inlet or slot into the PSTU, see chapter Reconfiguring the RBS
for IP Transmission in the RBS 2308 and RBS 2309 User’s Guide.
154
EN/LZT 720 0027 Uen R8A 2006-06-27