User's Manual Part 3

RBS 2308 and RBS 2309 User’s Guide
9.
Check that the voltage is 48 V
DC, using a multimeter.
P011187A
2 mm
10.3.12 SO TRXC RU:0/ RRU
This section describes how to localize an SO TRXC RU:0/ RRU fault.
Related R Us
The RUs listed below have higher priority than the RU described in this section.
If they are present, go to the related section before handling this RU.
If “SO CF RU:3/ Y link” appears in the OMT, then proceed with Section
10.3.3 SO CF RU:3/ Y Link on page 179
If “SO CF RU:31/ Environment” appears in the OMT, then proceed with
Section 10.3.7 SO CF RU:31/ Environment on page 185
If “SO CF RU:34/ IDB” appears in the OMT, then proceed with Section
10.3.8 SO CF RU:34/ IDB on page 187
Two TXs are used when TX diversity is activated, but only the first TX sends
the alarm. The fault is therefore located in a different RRU.
Displaying Fault Information
Display fault information according to Section 10.3.1 Reading Fault Status
on page 177.
Perform the following actions step-by-step until the fault ceases:
192
EN/LZT 720 0027 Uen R8A 2006-06-27