User's Manual Part 4

RBS 2308 and RBS 2309 User’s Guide
5. Press the Local/Re
mote button on the RRU to set the unit to remote mode.
Wait until the RF of
f indicator on the RRU interface panel goes off and the
Operational indic
ator shows a constant light.
6. Close the sunshie
lds.
Handling Replace
dUnits
The RRU should be r
eturned to Ericsson for repair with a repair delivery
note, LZF 084 84 (B
lue Tag) attached. Include a clear description of the fault
found. See Secti
on 10.6 Returning Hardware on page 255 for instructions
on completing a r
epair delivery note.
10.5.9 Replacing an RXB
P
This section des
cribes how to replace a faulty RXBP.
Taking the RRU o
ut of Service
1.
Open the sunshields.
2.
Contact the OMC operator to obtain permission to temporarily take
the TRXs connected to the RRU out of service. Wait until the RF off
indicator shows a constant light.
3.
Press the Local/Remote button
on the RRU to set the unit to
local mode. Wait until the local
indicator on the RRU shows a
constant light.
244 EN/LZT 720 0027 Uen R8A 2006-06-27