User's Manual Part 4

RBS 2308 and RBS 2309 User’s Guide
5. In the Final Config
uration Selection window, confirm that the cabinet and
antenna sector par
ameters are correct and click OK.
6. In the OMT dialog box asking Do you want to reuse data in the previous
configuration?, click Yes .
7. In the Reuse Site Specific Data window, select All Parameter and click OK.
Note that transmission parameters are not highlighted because IP is
selected as the transmission interface.
8. In the OMT dialog box asking Do you want to overwrite the IDB data in
the OMT?, click Yes.
9. On the Configuration menu, click Save IDB As... and save the new IDB in
a suitable file folder.
Installing the New IDB
Note: The RBS must be in l ocal mode to accept a new or modified IDB.
Note: Do not touch the RBS when any indicators are double-flashing. See
Section Double-Flash Indication of Function Changes in Chapter
Maintenance in RBS 2308 and RBS 2309 User’s Guide.
1. On the RBS 2000 menu, click Connect to connect the OMT logically to
the RBS.
2. On the Configuration menu, click Install IDB.
If the OMT detects inconsistencies between the RBS HW and the IDB, then
the differences are d isplayed in a window. However, the IDB in the RBS
can still be overwritten if an RBS/IDB inconsistency has been detected.
The IXU and RRUs remain in local mode after the IDB has been installed.
The RBS will perform an automatic reset after the IDB has been installed.
3. In the OMT dialogue box asking “Do you want to overwrite the IDB data in
the RBS?”, click Yes.
4. On the Configuration menu, click Site Specific Data and Display to open
the site_specific_data.txt window. Check that the parameters have been
correctly defined.
11.3.7 Putting the PSTU Into Remote Operation
To put the PSTU into remote operation, see chapter PSTU Startup in the
RBS 2308 and RBS 2309 User’s Guide.
268
EN/LZT 720 0027 Uen R8A 2006-06-27